Researcher Database

Researcher Profile and Settings

Master

Affiliation (Master)

  • Faculty of Health Sciences

Affiliation (Master)

  • Faculty of Health Sciences

researchmap

Profile and Settings

Profile and Settings

  • Name (Japanese)

    Takaaki
  • Name (Kana)

    Yoshimura
  • Name

    201801004909881645

Achievement

Awards

  • 2024/09 Hokkaido University Hokkaido University Research Encouragement Award for Young Researchers (Bronze)
     超低線量PET画像診断支援システムと生成AIの融合 
    受賞者: Yoshimura T;Sugimori H;Togo R;Hirata K
  • 2024/04 Japanese Society of Medical Physics 学生奨励賞
     A feasible study for classification of acute radiation-induced xerostomia risk based on a dosiomics 
    受賞者: Takagi S;Nakamoto T;Yasuda K;Yoshimura T;Tamura H;Aoyama H
  • 2024/04 日本放射線技術学会北海道支部 優秀研究賞
     マンモグラフィにおける石灰化識別のための半教師あり学習の適用と評価 
    受賞者: Sakaida M;Yoshimura T;Tang M;Ichikawa S;Sugimori H
  • 2024/03 Clinical AI Human Resources Development Program (CLAP), Graduate School of Medicine, Hokkaido University 優秀賞(ポスター部門)
     マンモグラフィ石灰化検出における半教師あり学習の適用と評価 
    受賞者: Sakaida M;Yoshimura T;Tang M;Ichikawa S;Sugimori H;Hirata K;Kudo K
  • 2024/03 Clinical AI Human Resources Development Program (CLAP), Graduate School of Medicine, Hokkaido University 優秀賞
     SRCNNを用いた短時間収集PET画像の画質改善: 臨床画像における定量性の検証 
    受賞者: Endo H;Yoshimura T;Tang M;Sugimori H;Hasegawa A;Kogame S;Magota K;Kimura R;Watanabe S;Hirata K;Kudo K
  • 2023/11 Japanese Society of Radiological Technology 第51回日本放射線技術学会秋季学術大会 座長推薦優秀研究
     Estimation of angles for oblique lumbar spine images using deep learning 
    受賞者: Moriya R;Yoshimura T;Tang M;Sugimori H
  • 2023/11 Japanese Society of Radiological Technology 第51回日本放射線技術学会秋季学術大会 座長推薦優秀研究
     心臓CT画像からの深層学習によるセグメンテーションを用いた大動脈弁自動推定法の検討 
    受賞者: Inomata S;Yoshimura T;Tang M;Ichikawa S;Sugimori H
  • 2023/10 Hokkaido University 第9回北海道大学部局横断シンポジウムベストポスター賞
     超解像深層学習を用いた低投与線量PET検査:臨床画像における定量性の検証 
    受賞者: Endo H;Yoshimura T;Sugiumori H;Magota K;Togo R;Hirata K;Kudo K
  • 2023/10 Hokkaido University Hokkaido University Research Encouragement Award for Young Researchers (Bronze)
     超解像深層学習を用いた低投与線量PET検査の実現に向けたシステム開発 
    受賞者: Yoshimura T;Sugimori H;Hirata K;Togo R
  • 2023/04 日本放射線技術学会北海道支部 優秀研究賞
     cine-MRIを用いた3D-CNNによる左室駆出率と右室駆出率推定 
    受賞者: 猪股壮一郎;吉村高明;唐明輝;杉森博行
  • 2023/03 Hokkaido University Graduation Research Excellence Presentation Award
     【学生・指導教員】人獣連携による高精度MR-CT画像変換技術開発~前立腺癌に対するMR画像誘導即時適応陽子線治療の実現に向けて~ 
    受賞者: 佐藤圭祐;吉村高明
  • 2022/11 第1回北大医療AIシンポジウム 優秀研究賞
     AIを用いた頭蓋内バイパス術の手術スキルの評価 
    受賞者: Takahari R;Sugimori H;Yoshimura T;Ogasawara K;Sugiyama T;Tang M
  • 2022/10 Japanese Society of Radiological Technology 第50回日本放射線技術学会秋季学術大会 座長推薦優秀研究
     Cine-MRIを用いた3D-CNNによる左室駆出率と右室駆出率推定 
    受賞者: Inomata S;Yoshimura T;Tang M;Sugimori H
  • 2022/10 北海道大学 Hokkaido University Research Encouragement Award for Young Researchers (Bronze)
     人獣連携によりMR画像-CT画像変換を高精度化する技術の開発~前立腺癌に対するMR画像誘導即時適応尿道線量低減陽子線治療の実現に向けて~ 
    受賞者: Yoshimura T;Shinbo G;Matsuura T;Hashimoto T;Nishioka K;Mori T;Kanehira T;Sugimori H
  • 2022/09 Japan Society of Medical Physics 奨励賞
     Construction of Super-Resolution Convolution Neural Network for Medical Radiation Exposure Reduction in whole-body PET examination. 
    受賞者: Endo H;Yoshimura T;Tang M;Sugimori H;Hasegawa A;Kogame S;Magota K;Kimura R;Watanabe S;Hirata K;Kudo K
  • 2022/03 日本放射線技術学会北海道支部 優秀研究賞
     SSIMを用いたPET画像に対する再構成条件の最適化 
    受賞者: 葛西悠平;名雲渓太;MANIAWSKI PJ;孫田惠一;平田健司;吉村高明;山品博子
  • 2022/03 Northern Advancement Center for Science & Technology (NOASTEC) NOASTEC Presidential Prize
     人工知能を用いた前立腺がんに対する 動体追跡陽子線治療計画技術の開発 
    受賞者: Yoshimmura T
  • 2022/02 令和3年度 家畜診療等技術全国研究集会 全国農業共済協会長賞
     子牛の急性腹症における超音波検査の有用性 
    受賞者: 吉村直彬;吉村高明;音井威重
  • 2021/10 Japanese Society of Radiological Technology 第49回日本放射線技術学会秋季学術大会 座長推薦優秀研究
     Preliminary study for the diagnosis-aid of the prostate MRI using deep learning 
    受賞者: Manabe K;Yoshimura T;Yamada T;Asami Y;Sugimori H
  • 2021/03 Hokkaido University Graduation Research Excellence Presentation Award
     【学生・指導教員】Deep Learningを用いた放射線治療計画用MRIの画質改善に関する研究 
    受賞者: Shouki Kogame;Takaaki Yoshimura
  • 2019/06 Particle Therapy Co-Operative Group(PTCOG) PTCOG58 Travel Fellowship Award
     
    受賞者: Yoshimura Takaaki

Published Papers

  • Li Yanjun, Takaaki Yoshimura, Yuto Horima, Hiroyuki Sugimori
    Electronics 13 (18) 3676 - 3676 2024/09/16 [Refereed]
  • Takaaki Yoshimura, Keigo Kondo, Takayuki Hashimoto, Kentaro Nishioka, Takashi Mori, Takahiro Kanehira, Taeko Matsuura, Seishin Takao, Hiroshi Tamura, Takuya Matsumoto, Kenneth Sutherland, Hidefumi Aoyama
    Journal of Radiation Research 65 (5) 676 - 688 0449-3060 2024/09/15 [Refereed]
     
    Abstract In proton craniospinal irradiation (CSI) for skeletally immature pediatric patients, a treatment plan should be developed to ensure that the dose is uniformly delivered to all vertebrae, considering the effects on bone growth balance. The technical (t) clinical target volume (CTV) is conventionally set by manually expanding the CTV from the entire intracranial space and thecal sac, based on the physician’s experience. However, there are differences in contouring methods among physicians. Therefore, we aimed to propose a new geometric target margin strategy. Nine pediatric patients with medulloblastoma who underwent proton CSI were enrolled. We measured the following water equivalent lengths for each vertebra in each patient: body surface to the dorsal spinal canal, vertebral limbus, ventral spinal canal and spinous processes. A simulated tCTV (stCTV) was created by assigning geometric margins to the spinal canal using the measurement results such that the vertebral limb and dose distribution coincided with a margin assigned to account for the uncertainty of the proton beam range. The stCTV with a growth factor (correlation between body surface area and age) and tCTV were compared and evaluated. The median values of each index for cervical, thoracic and lumber spine were: the Hausdorff distance, 9.14, 9.84 and 9.77 mm; mean distance-to-agreement, 3.26, 2.65 and 2.64 mm; Dice coefficient, 0.84, 0.81 and 0.82 and Jaccard coefficient, 0.50, 0.60 and 0.62, respectively. The geometric target margin setting method used in this study was useful for creating an stCTV to ensure consistent and uniform planning.
  • Miu Sakaida, Takaaki Yoshimura, Minghui Tang, Shota Ichikawa, Hiroyuki Sugimori, Kenji Hirata, Kohsuke Kudo
    Applied Sciences 14 (14) 5968 - 5968 2024/07/09 [Refereed][Not invited]
     
    Identifying calcifications in mammograms is crucial for early breast cancer detection, and semi-supervised learning, which utilizes a small dataset for supervised learning combined with deep learning, is anticipated to be an effective approach for automating this identification process. This study explored the impact of semi-supervised learning on identifying mammographic calcifications by including 712 mammographic images from 252 patients in public datasets. Initially, 212 mammogram images were segmented into patches and classified visually for calcification presence. A subset of these patches, derived from 169 mammogram images, was used to train a ResNet50-based classifier. The classifier was evaluated using patches generated from 43 mammograms as a test data set. Additionally, 500 more mammogram images were processed into patches and analyzed using the trained ResNet50 model, with semi-supervised learning applied to patches exceeding certain classification probabilities. This process aimed to enhance the classifier’s accuracy and achieve improvements over the initial model. The findings indicated that semi-supervised learning significantly benefits the accuracy of calcification detection in mammography, underscoring its utility in enhancing diagnostic methodologies.
  • Minghui Tang, Taku Sugiyama, Ren Takahari, Hiroyuki Sugimori, Takaaki Yoshimura, Katsuhiko Ogasawara, Kohsuke Kudo, Miki Fujimura
    Neurosurgical review 47 (1) 200 - 200 2024/05/09 [Refereed][Not invited]
     
    Appropriate needle manipulation to avoid abrupt deformation of fragile vessels is a critical determinant of the success of microvascular anastomosis. However, no study has yet evaluated the area changes in surgical objects using surgical videos. The present study therefore aimed to develop a deep learning-based semantic segmentation algorithm to assess the area change of vessels during microvascular anastomosis for objective surgical skill assessment with regard to the "respect for tissue." The semantic segmentation algorithm was trained based on a ResNet-50 network using microvascular end-to-side anastomosis training videos with artificial blood vessels. Using the created model, video parameters during a single stitch completion task, including the coefficient of variation of vessel area (CV-VA), relative change in vessel area per unit time (ΔVA), and the number of tissue deformation errors (TDE), as defined by a ΔVA threshold, were compared between expert and novice surgeons. A high validation accuracy (99.1%) and Intersection over Union (0.93) were obtained for the auto-segmentation model. During the single-stitch task, the expert surgeons displayed lower values of CV-VA (p < 0.05) and ΔVA (p < 0.05). Additionally, experts committed significantly fewer TDEs than novices (p < 0.05), and completed the task in a shorter time (p < 0.01). Receiver operating curve analyses indicated relatively strong discriminative capabilities for each video parameter and task completion time, while the combined use of the task completion time and video parameters demonstrated complete discriminative power between experts and novices. In conclusion, the assessment of changes in the vessel area during microvascular anastomosis using a deep learning-based semantic segmentation algorithm is presented as a novel concept for evaluating microsurgical performance. This will be useful in future computer-aided devices to enhance surgical education and patient safety.
  • Ryuma Moriya, Takaaki Yoshimura, Minghui Tang, Shota Ichikawa, Hiroyuki Sugimori
    Applied Sciences 14 (9) 3794 - 3794 2024/04/29 [Refereed]
     
    Background and Objectives: In lumbar spine radiography, the oblique view is frequently utilized to assess the presence of spondylolysis and the morphology of facet joints. It is crucial to instantly determine whether the oblique angle is appropriate for the evaluation and the necessity of retakes after imaging. This study investigates the feasibility of using a convolutional neural network (CNN) to estimate the angle of lumbar oblique images. Since there are no existing lumbar oblique images with known angles, we aimed to generate synthetic lumbar X-ray images at arbitrary angles from computed tomography (CT) images and to estimate the angles of these images using a trained CNN. Methods: Synthetic lumbar spine X-ray images were created from CT images of 174 individuals by rotating the lumbar spine from 0° to 60° in 5° increments. A line connecting the center of the spinal canal and the spinous process was used as the baseline to define the shooting angle of the synthetic X-ray images based on how much they were tilted from the baseline. These images were divided into five subsets and trained using ResNet50, a CNN for image classification, implementing 5-fold cross-validation. The models were trained for angle estimation regression and image classification into 13 classes at 5° increments from 0° to 60°. For model evaluation, mean squared error (MSE), root mean squared error (RMSE), and the correlation coefficient (r) were calculated for regression analysis, and the area under the curve (AUC) was calculated for classification. Results: In the regression analysis for angles from 0° to 60°, the MSE was 14.833 degree2, the RMSE was 3.820 degrees, and r was 0.981. The average AUC for the 13-class classification was 0.953. Conclusion: The CNN developed in this study was able to estimate the angle of an lumbar oblique image with high accuracy, suggesting its usefulness.
  • Michito Murayama, Hiroyuki Sugimori, Takaaki Yoshimura, Sanae Kaga, Hideki Shima, Satonori Tsuneta, Aoi Mukai, Yui Nagai, Shinobu Yokoyama, Hisao Nishino, Junichi Nakamura, Takahiro Sato, Ichizo Tsujino
    Echocardiography (Mount Kisco, N.Y.) 41 (4) e15812  2024/04 [Refereed][Not invited]
     
    BACKGROUND: Precapillary pulmonary hypertension (PH) is characterized by a sustained increase in right ventricular (RV) afterload, impairing systolic function. Two-dimensional (2D) echocardiography is the most performed cardiac imaging tool to assess RV systolic function; however, an accurate evaluation requires expertise. We aimed to develop a fully automated deep learning (DL)-based tool to estimate the RV ejection fraction (RVEF) from 2D echocardiographic videos of apical four-chamber views in patients with precapillary PH. METHODS: We identified 85 patients with suspected precapillary PH who underwent cardiac magnetic resonance imaging (MRI) and echocardiography. The data was divided into training (80%) and testing (20%) datasets, and a regression model was constructed using 3D-ResNet50. Accuracy was assessed using five-fold cross validation. RESULTS: The DL model predicted the cardiac MRI-derived RVEF with a mean absolute error of 7.67%. The DL model identified severe RV systolic dysfunction (defined as cardiac MRI-derived RVEF < 37%) with an area under the curve (AUC) of .84, which was comparable to the AUC of RV fractional area change (FAC) and tricuspid annular plane systolic excursion (TAPSE) measured by experienced sonographers (.87 and .72, respectively). To detect mild RV systolic dysfunction (defined as RVEF ≤ 45%), the AUC from the DL-predicted RVEF also demonstrated a high discriminatory power of .87, comparable to that of FAC (.90), and significantly higher than that of TAPSE (.67). CONCLUSION: The fully automated DL-based tool using 2D echocardiography could accurately estimate RVEF and exhibited a diagnostic performance for RV systolic dysfunction comparable to that of human readers.
  • Takaaki Yoshimura, Ryota Yamada, Rumiko Kinoshita, Taeko Matsuura, Takahiro Kanehira, Hiroshi Tamura, Kentaro Nishioka, Koichi Yasuda, Hiroshi Taguchi, Norio Katoh, Keiji Kobashi, Takayuki Hashimoto, Hidefumi Aoyama
    Journal of radiation research 2024/03/17 [Refereed][Not invited]
     
    This retrospective treatment-planning study was conducted to determine whether intensity-modulated proton therapy with robust optimization (ro-IMPT) reduces the risk of acute hematologic toxicity (H-T) and acute and late gastrointestinal toxicity (GI-T) in postoperative whole pelvic radiotherapy for gynecologic malignancies when compared with three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated X-ray (IMXT) and single-field optimization proton beam (SFO-PBT) therapies. All plans were created for 13 gynecologic-malignancy patients. The prescribed dose was 45 GyE in 25 fractions for 95% planning target volume in 3D-CRT, IMXT and SFO-PBT plans and for 99% clinical target volume (CTV) in ro-IMPT plans. The normal tissue complication probability (NTCP) of each toxicity was used as an in silico surrogate marker. Median estimated NTCP values for acute H-T and acute and late GI-T were 0.20, 0.94 and 0.58 × 10-1 in 3D-CRT; 0.19, 0.65 and 0.24 × 10-1 in IMXT; 0.04, 0.74 and 0.19 × 10-1 in SFO-PBT; and 0.06, 0.66 and 0.15 × 10-1 in ro-IMPT, respectively. Compared with 3D-CRT and IMXT plans, the ro-IMPT plan demonstrated significant reduction in acute H-T and late GI-T. The risk of acute GI-T in ro-IMPT plan is equivalent with IMXT plan. The ro-IMPT plan demonstrated potential clinical benefits for reducing the risk of acute H-T and late GI-T in the treatment of gynecologic malignances by reducing the dose to the bone marrow and bowel bag while maintaining adequate dose coverage to the CTV. Our results indicated that ro-IMPT may reduce acute H-T and late GI-T risk with potentially improving outcomes for postoperative gynecologic-malignancy patients with concurrent chemotherapy.
  • Yanjun Li, Takaaki Yoshimura, Yuto Horima, Hiroyuki Sugimori
    Algorithms 17 (3) 119 - 119 2024/03/13 [Refereed][Not invited]
     
    The detection of coronary artery stenosis is one of the most important indicators for the diagnosis of coronary artery disease. However, stenosis in branch vessels is often difficult to detect using computer-aided systems and even radiologists because of several factors, such as imaging angle and contrast agent inhomogeneity. Traditional coronary artery stenosis localization algorithms often only detect aortic stenosis and ignore branch vessels that may also cause major health threats. Therefore, improving the localization of branch vessel stenosis in coronary angiographic images is a potential development property. In this study, we propose a preprocessing approach that combines vessel enhancement and image fusion as a prerequisite for deep learning. The sensitivity of the neural network to stenosis features is improved by enhancing the blurry features in coronary angiographic images. By validating five neural networks, such as YOLOv4 and R-FCN-Inceptionresnetv2, our proposed method can improve the performance of deep learning network applications on the images from six common imaging angles. The results showed that the proposed method is suitable as a preprocessing method for coronary angiographic image processing based on deep learning and can be used to amend the recognition ability of the deep model for fine vessel stenosis.
  • Miu Sakaida, Takaaki Yoshimura, Minghui Tang, Shota Ichikawa, Hiroyuki Sugimori
    Algorithms 16 (10) 483 - 483 2023/10/18 [Refereed]
     
    Convolutional neural networks (CNNs) in deep learning have input pixel limitations, which leads to lost information regarding microcalcification when mammography images are compressed. Segmenting images into patches retains the original resolution when inputting them into the CNN and allows for identifying the location of calcification. This study aimed to develop a mammographic calcification detection method using deep learning by classifying the presence of calcification in the breast. Using publicly available data, 212 mammograms from 81 women were segmented into 224 × 224-pixel patches, producing 15,049 patches. These were visually classified for calcification and divided into five subsets for training and evaluation using fivefold cross-validation, ensuring image consistency. ResNet18, ResNet50, and ResNet101 were used for training, each of which created a two-class calcification classifier. The ResNet18 classifier achieved an overall accuracy of 96.0%, mammogram accuracy of 95.8%, an area under the curve (AUC) of 0.96, and a processing time of 0.07 s. The results of ResNet50 indicated 96.4% overall accuracy, 96.3% mammogram accuracy, an AUC of 0.96, and a processing time of 0.14 s. The results of ResNet101 indicated 96.3% overall accuracy, 96.1% mammogram accuracy, an AUC of 0.96, and a processing time of 0.20 s. This developed method offers quick, accurate calcification classification and efficient visualization of calcification locations.
  • Soichiro Inomata, Takaaki Yoshimura, Minghui Tang, Shota Ichikawa, Hiroyuki Sugimori
    Sensors 23 (14) 6580 - 6580 2023/07/21 [Refereed]
     
    Cardiac function indices must be calculated using tracing from short-axis images in cine-MRI. A 3D-CNN (convolutional neural network) that adds time series information to images can estimate cardiac function indices without tracing using images with known values and cardiac cycles as the input. Since the short-axis image depicts the left and right ventricles, it is unclear which motion feature is captured. This study aims to estimate the indices by learning the short-axis images and the known left and right ventricular ejection fractions and to confirm the accuracy and whether each index is captured as a feature. A total of 100 patients with publicly available short-axis cine images were used. The dataset was divided into training:test = 8:2, and a regression model was built by training with the 3D-ResNet50. Accuracy was assessed using a five-fold cross-validation. The correlation coefficient, MAE (mean absolute error), and RMSE (root mean squared error) were determined as indices of accuracy evaluation. The mean correlation coefficient of the left ventricular ejection fraction was 0.80, MAE was 9.41, and RMSE was 12.26. The mean correlation coefficient of the right ventricular ejection fraction was 0.56, MAE was 11.35, and RMSE was 14.95. The correlation coefficient was considerably higher for the left ventricular ejection fraction. Regression modeling using the 3D-CNN indicated that the left ventricular ejection fraction was estimated more accurately, and left ventricular systolic function was captured as a feature.
  • Takaaki Yoshimura, Keisuke Manabe, Hiroyuki Sugimori
    Applied Sciences 13 (14) 8028 - 8028 2023/07/09 [Refereed]
     
    The Gleason score (GS) is essential in categorizing prostate cancer risk using biopsy. The aim of this study was to propose a two-class GS classification (< and ≥GS 7) methodology using a three-dimensional convolutional neural network with semantic segmentation to predict GS non-invasively using multiparametric magnetic resonance images (MRIs). Four training datasets of T2-weighted images and apparent diffusion coefficient maps with and without semantic segmentation were used as test images. All images and lesion information were selected from a training cohort of the Society of Photographic Instrumentation Engineers, the American Association of Physicists in Medicine, and the National Cancer Institute (SPIE–AAPM–NCI) PROSTATEx Challenge dataset. Precision, recall, overall accuracy and area under the receiver operating characteristics curve (AUROC) were calculated from this dataset, which comprises publicly available prostate MRIs. Our data revealed that the GS ≥ 7 precision (0.73 ± 0.13) and GS < 7 recall (0.82 ± 0.06) were significantly higher using semantic segmentation (p < 0.05). Moreover, the AUROC in segmentation volume was higher than that in normal volume (ADCmap: 0.70 ± 0.05 and 0.69 ± 0.08, and T2WI: 0.71 ± 0.07 and 0.63 ± 0.08, respectively). However, there were no significant differences in overall accuracy between the segmentation and normal volume. This study generated a diagnostic method for non-invasive GS estimation from MRIs.
  • Kousuke Usui, Takaaki Yoshimura, Shota Ichikawa, Hiroyuki Sugimori
    Applied Sciences 13 (11) 6695 - 6695 2023/05/31 [Refereed]
     
    Although the widespread use of digital imaging has enabled real-time image display, images in chest X-ray examinations can be confirmed by the radiologist’s eyes. Considering the development of deep learning (DL) technology, its application will make it possible to immediately determine the need for a retake, which is expected to further improve examination throughput. In this study, we developed software for evaluating chest X-ray images to determine whether a repeat radiographic examination is necessary, based on the combined application of DL technologies, and evaluated its accuracy. The target population was 4809 chest images from a public database. Three classification models (CLMs) for lung field defects, obstacle shadows, and the location of obstacle shadows and a semantic segmentation model (SSM) for the lung field regions were developed using a fivefold cross validation. The CLM was evaluated using the overall accuracy in the confusion matrix, the SSM was evaluated using the mean intersection over union (mIoU), and the DL technology-combined software was evaluated using the total response time on this software (RT) per image for each model. The results of each CLM with respect to lung field defects, obstacle shadows, and obstacle shadow location were 89.8%, 91.7%, and 91.2%, respectively. The mIoU of the SSM was 0.920, and the software RT was 3.64 × 10−2 s. These results indicate that the software can immediately and accurately determine whether a chest image needs to be re-scanned.
  • Shota Ichikawa, Hiroyuki Sugimori, Koki Ichijiri, Takaaki Yoshimura, Akio Nagaki
    Journal of applied clinical medical physics 24 (6) e13978  2023/04/05 [Refereed]
     
    PURPOSE: Given the potential risk of motion artifacts, acquisition time reduction is desirable in pediatric 99m Tc-dimercaptosuccinic acid (DMSA) scintigraphy. The aim of this study was to evaluate the performance of predicted full-acquisition-time images from short-acquisition-time pediatric 99m Tc-DMSA planar images with only 1/5th acquisition time using deep learning in terms of image quality and quantitative renal uptake measurement accuracy. METHODS: One hundred and fifty-five cases that underwent pediatric 99m Tc-DMSA planar imaging as dynamic data for 10 min were retrospectively collected for the development of three deep learning models (DnCNN, Win5RB, and ResUnet), and the generation of full-time images from short-time images. We used the normalized mean squared error (NMSE), peak signal-to-noise ratio (PSNR), and structural similarity index metrics (SSIM) to evaluate the accuracy of the predicted full-time images. In addition, the renal uptake of 99m Tc-DMSA was calculated, and the difference in renal uptake from the reference full-time images was assessed using scatter plots with Pearson correlation and Bland-Altman plots. RESULTS: The predicted full-time images from the deep learning models showed a significant improvement in image quality compared to the short-time images with respect to the reference full-time images. In particular, the predicted full-time images obtained by ResUnet showed the lowest NMSE (0.4 [0.4-0.5] %) and the highest PSNR (55.4 [54.7-56.1] dB) and SSIM (0.997 [0.995-0.997]). For renal uptake, an extremely high correlation was achieved in all short-time and three predicted full-time images (R2  > 0.999 for all). The Bland-Altman plots showed the lowest bias (-0.10) of renal uptake in ResUnet, while short-time images showed the lowest variance (95% confidence interval: -0.14, 0.45) of renal uptake. CONCLUSIONS: Our proposed method is capable of producing images that are comparable to the original full-acquisition-time images, allowing for a reduction of acquisition time/injected dose in pediatric 99m Tc-DMSA planar imaging.
  • Kousuke Usui, Takaaki Yoshimura, Minghui Tang, Hiroyuki Sugimori
    Applied Sciences 13 (3) 1753 - 1753 2023/01/30 [Refereed]
     
    Estimation of human age is important in the fields of forensic medicine and the detection of neurodegenerative diseases of the brain. Particularly, the age estimation methods using brain magnetic resonance (MR) images are greatly significant because these methods not only are noninvasive but also do not lead to radiation exposure. Although several age estimation methods using brain MR images have already been investigated using deep learning, there are no reports involving younger subjects such as children. This study investigated the age estimation method using T1-weighted (sagittal plane) two-dimensional brain MR imaging (MRI) of 1000 subjects aged 5–79 (31.64 ± 18.04) years. This method uses a regression model based on ResNet-50, which estimates the chronological age (CA) of unknown brain MR images by training brain MR images corresponding to the CA. The correlation coefficient, coefficient of determination, mean absolute error, and root mean squared error were used as the evaluation indices of this model, and the results were 0.9643, 0.9299, 5.251, and 6.422, respectively. The present study showed the same degree of correlation as those of related studies, demonstrating that age estimation can be performed for a wide range of ages with higher estimation accuracy.
  • Takaaki Yoshimura, Kentaro Nishioka, Takayuki Hashimoto, Takashi Mori, Shoki Kogame, Kazuya Seki, Hiroyuki Sugimori, Hiroko Yamashina, Yusuke Nomura, Fumi Kato, Kohsuke Kudo, Shinichi Shimizu, Hidefumi Aoyama
    PloS one 18 (1) e0280076  2023/01 [Refereed]
     
    In urethra-sparing radiation therapy, prostatic urinary tract visualization is important in decreasing the urinary side effect. A methodology has been developed to visualize the prostatic urinary tract using post-urination magnetic resonance imaging (PU-MRI) without a urethral catheter. This study investigated whether the combination of PU-MRI and super-resolution (SR) deep learning models improves the visibility of the prostatic urinary tract. We enrolled 30 patients who had previously undergone real-time-image-gated spot scanning proton therapy by insertion of fiducial markers. PU-MRI was performed using a non-contrast high-resolution two-dimensional T2-weighted turbo spin-echo imaging sequence. Four different SR deep learning models were used: the enhanced deep SR network (EDSR), widely activated SR network (WDSR), SR generative adversarial network (SRGAN), and residual dense network (RDN). The complex wavelet structural similarity index measure (CW-SSIM) was used to quantitatively assess the performance of the proposed SR images compared to PU-MRI. Two radiation oncologists used a 1-to-5 scale to subjectively evaluate the visibility of the prostatic urinary tract. Cohen's weighted kappa (k) was used as a measure of agreement of inter-operator reliability. The mean CW-SSIM in EDSR, WDSR, SRGAN, and RDN was 99.86%, 99.89%, 99.30%, and 99.67%, respectively. The mean prostatic urinary tract visibility scores of the radiation oncologists were 3.70 and 3.53 for PU-MRI (k = 0.93), 3.67 and 2.70 for EDSR (k = 0.89), 3.70 and 2.73 for WDSR (k = 0.88), 3.67 and 2.73 for SRGAN (k = 0.88), and 4.37 and 3.73 for RDN (k = 0.93), respectively. The results suggest that SR images using RDN are similar to the original images, and the SR deep learning models subjectively improve the visibility of the prostatic urinary tract.
  • Naoaki Yoshimura, Takeshi Tsuka, Takaaki Yoshimura, Takeshige Otoi
    Animals 12 (19) 2489 - 2489 2022/09/20 [Refereed][Not invited]
     
    This study investigated the clinical efficacy of abdominal ultrasonography for abomasal dilation in three calves, intestinal volvulus in five calves, intussusception in one calf, and internal hernia in one calf. In the abdominal ultrasonograms of the abomasal dilation cases, this disease was commonly characterized by severely extended lumens, including heterogeneously hyperechoic ingesta without intraluminal accumulations of gas. In the animals with intestinal volvulus and intussusception, a to-and-fro flow was observed to be a common ultrasonographic characteristic that led to suspicion of an intestinal obstruction. The use of abdominal ultrasonography for five cases with intestinal volvulus gave no reason to suspect this disease, despite its efficacy in one case, based on an acutely angled narrowing. Although three of five animals with intestinal volvulus had intestinal ruptures, no ultrasonographic evidence could be obtained. When abdominal ultrasonography was used for one case with intussusception, this pathological condition could be strongly suspected, as a “target” sign was observed. This finding supported surgical intervention for this case, followed by treatment with manual reduction, resulting in a favorable outcome. In terms of the differential and definitive diagnosis for various intestinal diseases, abdominal ultrasonography may be poor at providing indicative evidence, but very helpful for confirming intestinal obstruction.
  • Hiroshi Tamura, Keiji Kobashi, Kentaro Nishioka, Takaaki Yoshimura, Takayuki Hashimoto, Shinichi Shimizu, Yoichi M. Ito, Yoshikazu Maeda, Makoto Sasaki, Kazutaka Yamamoto, Hiroyasu Tamamura, Hidefumi Aoyama, Hiroki Shirato
    Journal of Applied Clinical Medical Physics 23 (4) e13531  1526-9914 2022/04 [Refereed][Not invited]
     
    PURPOSE: To evaluate the dosimetric advantages of daily adaptive radiotherapy (DART) in intensity-modulated proton therapy (IMPT) for high-risk prostate cancer by comparing estimated doses of the conventional non-adaptive radiotherapy (NART) that irradiates according to an original treatment plan through the entire treatment and the DART that uses an adaptive treatment plan generated by using daily CT images acquired before each treatment. METHODS: Twenty-three patients with prostate cancer were included. A treatment plan with 63 Gy (relative biological effectiveness (RBE)) in 21 fractions was generated using treatment planning computed tomography (CT) images assuming that all patients had high-risk prostate cancer for which the clinical target volume (CTV) needs to include prostate and the seminal vesicle (SV) in our treatment protocol. Twenty-one adaptive treatment plans for each patient (total 483 data sets) were generated using daily CT images, and dose distributions were calculated. Using a 3 mm set-up uncertainty in the robust optimization, the doses to the CTV, prostate, SV, rectum, and bladder were compared. RESULTS: Estimated accumulated doses of NART and DART in the 23 patients were 60.81 ± 3.47 Gy (RBE) and 63.24 ± 1.04 Gy (RBE) for CTV D99 (p < 0.01), 62.99 ± 1.28 Gy (RBE) and 63.43 ± 1.33 Gy (RBE) for the prostate D99 (p = 0.2529), and 59.07 ± 5.19 Gy (RBE) and 63.17 ± 1.04 Gy (RBE) for SV D99 (p < 0.001). No significant differences were observed between NART and DART in the estimated accumulated dose for the rectum and bladder. CONCLUSION: Compared with the NART, DART was shown to be a useful approach that can maintain the dose coverage to the target without increasing the dose to the organs at risk (OAR) using the 3 mm set-up uncertainty in the robust optimization in patients with high-risk prostate cancer.
  • Takaaki Yoshimura, Atsushi Hasegawa, Shoki Kogame, Keiichi Magota, Rina Kimura, Shiro Watanabe, Kenji Hirata, Hiroyuki Sugimori
    Diagnostics 12 (4) 872 - 872 2022/03/31 [Refereed]
     
    In positron emission tomography (PET) imaging, image quality correlates with the injected [18F]-fluorodeoxyglucose (FDG) dose and acquisition time. If image quality improves from short-acquisition PET images via the super-resolution (SR) deep learning technique, it is possible to reduce the injected FDG dose. Therefore, the aim of this study was to clarify whether the SR deep learning technique could improve the image quality of the 50%-acquisition-time image to the level of that of the 100%-acquisition-time image. One-hundred-and-eight adult patients were enrolled in this retrospective observational study. The supervised data were divided into nine subsets for nested cross-validation. The mean peak signal-to-noise ratio and structural similarity in the SR-PET image were 31.3 dB and 0.931, respectively. The mean opinion scores of the 50% PET image, SR-PET image, and 100% PET image were 3.41, 3.96, and 4.23 for the lung level, 3.31, 3.80, and 4.27 for the liver level, and 3.08, 3.67, and 3.94 for the bowel level, respectively. Thus, the SR-PET image was more similar to the 100% PET image and subjectively improved the image quality, as compared to the 50% PET image. The use of the SR deep-learning technique can reduce the injected FDG dose and thus lower radiation exposure.
  • Yusuke Asami, Takaaki Yoshimura, Keisuke Manabe, Tomonari Yamada, Hiroyuki Sugimori
    Applied Sciences 11 (24) 12006 - 12006 2021/12/16 [Refereed]
     
    Purpose: A deep learning technique was used to analyze the triceps surae muscle. The devised interpolation method was used to determine muscle’s volume and verify the usefulness of the method. Materials and Methods: Thirty-eight T1-weighted cross-sectional magnetic resonance images of the triceps of the lower leg were divided into three classes, i.e., gastrocnemius lateralis (GL), gastrocnemius medialis (GM), and soleus (SOL), and the regions of interest (ROIs) were manually defined. The supervised images were classified as per each patient. A total of 1199 images were prepared. Six different datasets separated patient-wise were prepared for K-fold cross-validation. A network model of the DeepLabv3+ was used for training. The images generated by the created model were divided as per each patient and classified into each muscle types. The model performance and the interpolation method were evaluated by calculating the Dice similarity coefficient (DSC) and error rates of the volume of the predicted and interpolated images, respectively. Results: The mean DSCs for the predicted images were >0.81 for GM and SOL and 0.71 for GL. The mean error rates for volume were approximately 11% for GL, SOL, and total error and 23% for GL. DSCs in the interpolated images were >0.8 for all muscles. The mean error rates of volume were <10% for GL, SOL, and total error and 18% for GM. There was no significant difference between the volumes obtained from the supervised images and interpolated images. Conclusions: Using the semantic segmentation of the deep learning technique, the triceps were detected with high accuracy and the interpolation method used in this study to find the volume was useful.
  • Kentaro Nishioka, Kento Gotoh, Takayuki Hashimoto, Takashige Abe, Takahiro Osawa, Ryuji Matsumoto, Isao Yokota, Norio Katoh, Rumiko Kinoshita, Koichi Yasuda, Toshiaki Yakabe, Takaaki Yoshimura, Seishin Takao, Nobuo Shinohara, Hidefumi Aoyama, Shinichi Shimizu, Hiroki Shirato
    BJR|Open 3 (1) 20210064 - 20210064 2021/11 [Refereed]
     
    Objectives: The purpose of this study is to investigate whether verbal instructions are sufficient for bladder volume (BV) control not to deteriorate prostate position reproducibility in image-guided spot scanning proton therapy (SSPT) for localized prostate cancer. Methods: A total of 268 treatment sessions in 12 consecutive prostate cancer patients who were treated with image-guided SSPT with fiducial markers were retrospectively analyzed. In addition to strict rectal volume control procedures, simple verbal instructions to void urine one hour before the treatment were used here. The BV was measured by a Bladder Scan just before the treatment, and the prostate motion was measured by intraprostatic fiducial markers and two sets of X-ray fluoroscopy images. The correlation between the BV change and prostate motion was assessed by linear mixed-effects models and systematic and random errors according to the reproducibility of the BV. Results: The mean absolute BV change during treatment was from −98.7 to 86.3 ml (median 7.1 ml). The mean absolute prostate motion of the patients in the left-right direction was −1.46 to 1.85 mm; in the cranial-caudal direction it was −6.10 to 3.65 mm, and in the anteroposterior direction −1.90 to 5.23 mm. There was no significant relationship between the BV change and prostate motion during SSPT. The early and late genitourinary and gastrointestinal toxicity was minimal with a minimum follow up of 4.57 years. Conclusions: Simple verbal instructions about urination was suggested to be sufficient to control the BV not to impact on the prostate motion and clinical outcomes in image-guided SSPT. Careful attention to BV change is still needed when the seminal vesicle is to be treated. Advances in knowledge: Our data demonstrated that there was no apparent relationship between BV changes and prostate position reproducibility and simple verbal instruction about urination could be sufficient for image-guided SSPT.
  • Takaaki Yoshimura, Kentaro Nishioka, Takayuki Hashimoto, Kazuya Seki, Shouki Kogame, Sodai Tanaka, Takahiro Kanehira, Masaya Tamura, Seishin Takao, Taeko Matsuura, Keiji Kobashi, Fumi Kato, Hidefumi Aoyama, Shinichi Shimizu
    Physics and Imaging in Radiation Oncology 20 23 - 29 2405-6316 2021/10 [Refereed]
     
    BACKGROUND AND PURPOSE: Urethra-sparing radiation therapy for localized prostate cancer can reduce the risk of radiation-induced genitourinary toxicity by intentionally underdosing the periurethral transitional zone. We aimed to compare the clinical impact of a urethra-sparing intensity-modulated proton therapy (US-IMPT) plan with that of conventional clinical plans without urethral dose reduction. MATERIALS AND METHODS: This study included 13 patients who had undergone proton beam therapy. The prescribed dose was 63 GyE in 21 fractions for 99% of the clinical target volume. To compare the clinical impact of the US-IMPT plan with that of the conventional clinical plan, tumor control probability (TCP) and normal tissue complication probability (NTCP) were calculated with a generalized equivalent uniform dose-based Lyman-Kutcher model using dose volume histograms. The endpoints of these model parameters for the rectum, bladder, and urethra were fistula, contraction, and urethral stricture, respectively. RESULTS: The mean NTCP value for the urethra in US-IMPT was significantly lower than that in the conventional clinical plan (0.6% vs. 1.2%, p < 0.05). There were no statistically significant differences between the conventional and US-IMPT plans regarding the mean minimum dose for the urethra with a 3-mm margin, TCP value, and NTCP value for the rectum and bladder. Additionally, the target dose coverage of all plans in the robustness analysis was within the clinically acceptable range. CONCLUSIONS: Compared with the conventional clinically applied plans, US-IMPT plans have potential clinical advantages and may reduce the risk of genitourinary toxicities, while maintaining the same TCP and NTCP in the rectum and bladder.
  • Takaaki Yoshimura, Honoka Tamori, Yasuhiro Morii, Takayuki Hashimoto, Shinichi Shimizu, Katsuhiko Ogasawara
    Journal of radiation research 2021/09/29 [Refereed]
     
    Compared to conventional X-ray therapy, proton beam therapy (PBT) has more clinical and physical advantages such as irradiation dose reduction to normal tissues for pediatric medulloblastoma. However, PBT is expensive. We aimed to compare the cost-effectiveness of PBT for pediatric medulloblastoma with that of conventional X-ray therapy, while focusing on radiation-induced secondary cancers, which are rare, serious and negatively affect a patient's quality of life (QOL). Based on a systematic review, a decision tree model was used for the cost-effectiveness analysis. This analysis was performed from the perspective of health care payers; the cost was estimated from medical fees. The target population was pediatric patients with medulloblastoma below 14 years old. The time horizon was set at 7.7 years after medulloblastoma treatment. The primary outcome was the incremental cost-effectiveness ratio (ICER), which was defined as the ratio of the difference in cost and lifetime attributable risk (LAR) between conventional X-ray therapy and PBT. The discount rate was set at 2% annually. Sensitivity analyses were performed to model uncertainty. Cost and LAR in conventional X-ray therapy and PBT were Japanese yen (JPY) 1 067 608 and JPY 2436061 and 42% and 7%, respectively. The ICER was JPY 3856398/LAR. In conclusion, PBT is more cost-effective than conventional X-ray therapy in reducing the risk of radiation-induced secondary cancers in pediatric medulloblastoma. Thus, our constructed ICER using LAR is one of the valid indicators for cost-effectiveness analysis in radiation-induced secondary cancer.
  • Naoaki Yoshimura, Takeshi Tsuka, Yuji Sunden, Takehito Morita, Md Shafiqul Islam, Osamu Yamato, Takaaki Yoshimura
    The Journal of veterinary medical science 2021/09/14 [Refereed]
     
    The aim of this study was to evaluate the impacts of ophthalmic findings obtained from both macroscopic examination and ocular ultrasonography when diagnosing bovine endophthalmitis. A newborn crossbreed (Japanese black and Holstein breeds) calf was suspected of visual impairment and central nervous system (CNS) symptoms, such as decreased activity and weak drinking performance. This calf was found to display macroscopic signs, such as clouded lens, convergent strabismus, and horizontal nystagmus, in both eyes. On ocular ultrasonography of both eyes, a V-shaped, thickened, hyperechoic structure was present in the anechoic vitreous humors, indicating retinal detachment. The animal died 4 days after the examination. Sepsis was evident in this case, as Escherichia coli was isolated from multiple organs. The autopsy and histological examination revealed meningitis, encephalitis, and secondary hydrocephalus in the CNS, and endophthalmitis and retinal detachment in both eyes. In this case, the ophthalmic findings did not provide definitive evidence for a diagnosis of endophthalmitis. However, this study indicated that retinal detachment might be an ultrasonographic finding that is suggestive of bovine endophthalmitis.
  • Sodai Tanaka, Naoki Miyamoto, Yuto Matsuo, Takaaki Yoshimura, Seishin Takao, Taeko Matsuura
    Physics in medicine and biology 66 (18) 2021/09/09 [Refereed]
     
    Increasing numbers of proton imaging research studies are being conducted for accurate proton range determination in proton therapy treatment planning. However, there is no proton imaging system that deals with motion artifacts. In this study, a gated proton imaging system was developed and the first experimental results of proton radiography were obtained for a moving object without motion artifacts. A motion management system using dual x-ray fluoroscopy for detecting a spherical gold fiducial marker was introduced and the proton beam was gated in accordance with the motion of the object. To demonstrate the performance of the gated proton imaging system, gated proton radiography images of a moving phantom were acquired experimentally, and the motion artifacts clearly were diminished. Also, the factors causing image deteriorations were evaluated focusing on the new gating system developed here, and the main factor was identified as the latency (with a maximum value of 93 ms) between the ideal gating signal according to the actual marker position and the actual gating signal. The possible deterioration due to the latency of the proton imaging system and proton beam irradiation was small owing to appropriate setting of the time structure.
  • Takaaki Yoshimura, Kentaro Nishioka, Takayuki Hashimoto, Taro Fujiwara, Kinya Ishizaka, Hiroyuki Sugimori, Shoki Kogame, Kazuya Seki, Hiroshi Tamura, Sodai Tanaka, Yuto Matsuo, Yasuhiro Dekura, Fumi Kato, Hidefumi Aoyama, Shinichi Shimizu
    Physics and Imaging in Radiation Oncology 18 1 - 4 2021/04 [Refereed]
     
    The urethra position may shift due to the presence/absence of the catheter. Our proposed post-urination-magnetic resonance imaging (PU-MRI) technique is possible to identify the urethra without catheter. We aimed to verify the inter-operator difference in contouring the urethra by PU-MRI. The mean values of the evaluation indices of dice similarity coefficient, mean slice-wise Hausdorff distance, and center coordinates were 0.93, 0.17 mm, and 0.36 mm for computed tomography, and 0.75, 0.44 mm, and 1.00 mm for PU-MRI. Therefore, PU-MRI might be useful for identifying the prostatic urinary tract without using a urethral catheter. Clinical trial registration: Hokkaido University Hospital for Clinical Research (018-0221).
  • Takaaki Yoshimura, Noriyo Colley, Shunsuke Komizunai, Shinji Ninomiya, Satoshi Kanai, Atsushi Konno, Koichi Yasuda, Hiroshi Taguchi, Takayuki Hashimoto, Shinichi Shimizu
    PloS one 16 (3) e0249010  2021 [Refereed]
     
    Tracheal suctioning is an important procedure to maintain airway patency by removing secretions. Today, suctioning operators include not only medical staff, but also family caregivers. The use of a simulation system has been noted to be the most effective way to learn the tracheal suctioning technique for operators. While the size of the trachea varies across different age groups, the artificial trachea model in the simulation system has only one fixed model. Thus, this study aimed to construct multiple removable trachea models according to different age groups. We enrolled 20 patients who had previously received proton beam therapy in our institution and acquired the treatment planning computed tomography (CT) image data. To construct the artificial trachea model for three age groups (children, adolescents and young adults, and adults), we analyzed the three-dimensional coordinates of the entire trachea, tracheal carina, and the end of the main bronchus. We also analyzed the diameter of the trachea and main bronchus. Finally, we evaluated the accuracy of the model by analyzing the difference between the constructed model and actual measurements. The trachea model was 8 cm long for children and 12 cm for adolescents and young adults, and for adults. The angle between the trachea and bed was about 20 degrees, regardless of age. The mean model accuracy was less than 0.4 cm. We constructed detachable artificial trachea models for three age groups for implementation in the endotracheal suctioning training environment simulator (ESTE-SIM) based on the treatment planning CT image. Our constructed artificial trachea models will be able to provide a simulation environment for various age groups in the ESTE-SIM.
  • Hideki Minatogawa, Koichi Yasuda, Yasuhiro Dekura, Seishin Takao, Taeko Matsuura, Takaaki Yoshimura, Ryusuke Suzuki, Isao Yokota, Noriyuki Fujima, Rikiya Onimaru, Shinichi Shimizu, Hidefumi Aoyama, Hiroki Shirato
    Journal of applied clinical medical physics 22 (1) 174 - 183 2021/01 [Refereed]
     
    PURPOSE: To investigate potential advantages of adaptive intensity-modulated proton beam therapy (A-IMPT) by comparing it to adaptive intensity-modulated X-ray therapy (A-IMXT) for nasopharyngeal carcinomas (NPC). METHODS: Ten patients with NPC treated with A-IMXT (step and shoot approach) and concomitant chemotherapy between 2014 and 2016 were selected. In the actual treatment, 46 Gy in 23 fractions (46Gy/23Fx.) was prescribed using the initial plan and 24Gy/12Fx was prescribed using an adapted plan thereafter. New treatment planning of A-IMPT was made for the same patients using equivalent dose fractionation schedule and dose constraints. The dose volume statistics based on deformable images and dose accumulation was used in the comparison of A-IMXT with A-IMPT. RESULTS: The means of the Dmean of the right parotid gland (P < 0.001), right TM joint (P < 0.001), left TM joint (P < 0.001), oral cavity (P < 0.001), supraglottic larynx (P = 0.001), glottic larynx (P < 0.001), , middle PCM (P = 0.0371), interior PCM (P < 0.001), cricopharyngeal muscle (P = 0.03643), and thyroid gland (P = 0.00216), in A-IMPT are lower than those of A-IMXT, with statistical significance. The means of, D0.03cc , and Dmean of each sub portion of auditory apparatus and D30% for Eustachian tube and D0.5cc for mastoid volume in A-IMPT are significantly lower than those of A-IMXT. The mean doses to the oral cavity, supraglottic larynx, and glottic larynx were all reduced by more than 20 Gy (RBE = 1.1). CONCLUSIONS: An adaptive approach is suggested to enhance the potential benefit of IMPT compared to IMXT to reduce adverse effects for patients with NPC.
  • Sodai Tanaka, Yoshiyuki Noto, Satoru Utsunomiya, Takaaki Yoshimura, Taeko Matsuura, Masatoshi Saito
    Physics in medicine and biology 65 (23) 235046 - 235046 0031-9155 2020/12/18 [Refereed]
     
    To achieve an accurate stopping power ratio (SPR) prediction in particle therapy treatment planning, we previously proposed a simple conversion to the SPR from dual-energy (DE) computed tomography (CT) data via electron density and effective atomic number (Z eff) calibration (DEEDZ-SPR). This study was conducted to carry out an initial implementation of the DEEDZ-SPR conversion method with a clinical treatment planning system (TPS; VQA, Hitachi Ltd., Tokyo) for proton beam therapy. Consequently, this paper presents a proton therapy plan for an anthropomorphic phantom to evaluate the stability of the dose calculations obtained by the DEEDZ-SPR conversion against the variation of the calibration phantom size. Dual-energy x-ray CT images were acquired using a dual-source CT (DSCT) scanner. A single-energy CT (SECT) scan using the same DSCT scanner was also performed to compare the DEEDZ-SPR conversion with the SECT-based SPR (SECT-SPR) conversion. The scanner-specific parameters necessary for the SPR calibration were obtained from the CT images of tissue substitutes in a calibration phantom. Two calibration phantoms with different sizes (a 33 cm diameter phantom and an 18 cm diameter phantom) were used for the SPR calibrations to investigate the beam-hardening effect on dosimetric uncertainties. Each set of calibrated SPR data was applied to the proton therapy plan designed using the VQA TPS with a pencil beam algorithm for the anthropomorphic phantom. The treatment plans with the SECT-SPR conversion exhibited discrepancies between the dose distributions and the dose-volume histograms (DVHs) of the 33 cm and 18 cm phantom calibrations. In contrast, the corresponding dose distributions and the DVHs obtained using the DEEDZ-SPR conversion method coincided almost perfectly with each other. The DEEDZ-SPR conversion appears to be a promising method for providing proton dose plans that are stable against the size variations of the calibration phantom and the patient.
  • Takaaki Yoshimura, Shinichi Shimizu, Takayuki Hashimoto, Kentaro Nishioka, Norio Katoh, Hiroshi Taguchi, Koichi Yasuda, Taeko Matsuura, Seishin Takao, Masaya Tamura, Sodai Tanaka, Yoichi M Ito, Yuto Matsuo, Hiroshi Tamura, Kenji Horita, Kikuo Umegaki, Hiroki Shirato
    Journal of applied clinical medical physics 21 (12) 10 - 19 2020/12 [Refereed]
     
    A synchrotron-based real-time image gated spot-scanning proton beam therapy (RGPT) system with inserted fiducial markers can irradiate a moving tumor with high accuracy. As gated treatments increase the beam delivery time, this study aimed to investigate the frequency of intra-field adjustments corresponding to the baseline shift or drift and the beam delivery efficiency of a synchrotron-based RGPT system. Data from 118 patients corresponding to 127 treatment plans and 2810 sessions between October 2016 and March 2019 were collected. We quantitatively analyzed the proton beam delivery time, the difference between the ideal beam delivery time based on a simulated synchrotron magnetic excitation pattern and the actual treatment beam delivery time, frequency corresponding to the baseline shift or drift, and the gating efficiency of the synchrotron-based RGPT system according to the proton beam delivery machine log data. The mean actual beam delivery time was 7.1 min, and the simulated beam delivery time in an ideal environment with the same treatment plan was 2.9 min. The average difference between the actual and simulated beam delivery time per session was 4.3 min. The average frequency of intra-field adjustments corresponding to baseline shift or drift and beam delivery efficiency were 21.7% and 61.8%, respectively. Based on our clinical experience with a synchrotron-based RGPT system, we determined the frequency corresponding to baseline shift or drift and the beam delivery efficiency using the beam delivery machine log data. To maintain treatment accuracy within ± 2.0 mm, intra-field adjustments corresponding to baseline shift or drift were required in approximately 20% of cases. Further improvements in beam delivery efficiency may be realized by shortening the beam delivery time.
  • Takaaki Yoshimura, Shinichi Shimizu, Takayuki Hashimoto, Kentaro Nishioka, Norio Katoh, Tetsuya Inoue, Hiroshi Taguchi, Koichi Yasuda, Taeko Matsuura, Seishin Takao, Masaya Tamura, Yoichi M Ito, Yuto Matsuo, Hiroshi Tamura, Kenji Horita, Kikuo Umegaki, Hiroki Shirato
    Journal of applied clinical medical physics 21 (2) 38 - 49 2020/02 [Refereed][Not invited]
     
    We developed a synchrotron-based real-time-image gated-spot-scanning proton-beam therapy (RGPT) system and utilized it to clinically operate on moving tumors in the liver, pancreas, lung, and prostate. When the spot-scanning technique is linked to gating, the beam delivery time with gating can increase, compared to that without gating. We aim to clarify whether the total treatment process can be performed within approximately 30 min (the general time per session in several proton therapy facilities), even for gated-spot-scanning proton-beam delivery with implanted fiducial markers. Data from 152 patients, corresponding to 201 treatment plans and 3577 sessions executed from October 2016 to June 2018, were included in this study. To estimate the treatment process time, we utilized data from proton beam delivery logs during the treatment for each patient. We retrieved data, such as the disease site, total target volume, field size at the isocenter, and the number of layers and spots for each field, from the treatment plans. We quantitatively analyzed the treatment process, which includes the patient load (or setup), bone matching, marker matching, beam delivery, patient unload, and equipment setup, using the data obtained from the log data. Among all the cases, 90 patients used the RGPT system (liver: n = 34; pancreas: n = 5; lung: n = 4; and prostate: n = 47). The mean and standard deviation (SD) of the total treatment process time for the RGPT system was 30.3 ± 7.4 min, while it was 25.9 ± 7.5 min for those without gating treatment, excluding craniospinal irradiation (CSI; head and neck: n = 16, pediatric: n = 31, others: n = 15); for CSI (n = 11) with two or three isocenters, the process time was 59.9 ± 13.9 min. Our results demonstrate that spot-scanning proton therapy with a gating function can be achieved in approximately 30-min time slots.
  • Yasuhiro Dekura, Kentaro Nishioka, Takayuki Hashimoto, Naoki Miyamoto, Ryusuke Suzuki, Takaaki Yoshimura, Ryuji Matsumoto, Takahiro Osawa, Takashige Abe, Yoichi M Ito, Nobuo Shinohara, Hiroki Shirato, Shinichi Shimizu
    Radiation oncology (London, England) 14 (1) 226 - 226 2019/12/12 [Refereed][Not invited]
     
    PURPOSE: To determine the best method to contour the planning organ at risk volume (PRV) for the urethra, this study aimed to investigate the displacement of a Foley catheter in the urethra with a soft and thin guide-wire. METHODS: For each patient, the study used two sets of computed tomography (CT) images for radiation treatment planning (RT-CT): (1) set with a Foley urethral catheter (4.0 mm diameter) plus a guide-wire (0.46 mm diameter) in the first RT-CT and (2) set with a guide-wire alone in the second CT recorded 2 min after the first RT-CT. Using three fiducial markers in the prostate for image fusion, the displacement between the catheter and the guide-wire in the prostatic urethra was calculated. In 155 consecutive patients treated between 2011 and 2017, 5531 slices of RT-CT were evaluated. RESULTS: Assuming that ≥3.0 mm of difference between the catheter and the guide-wire position was a significant displacement, the urethra with the catheter was displaced significantly from the urethra with the guide-wire alone in > 20% of the RT-CT slices in 23.2% (36/155) of the patients. The number of patients who showed ≥3.0 mm anterior displacement with the catheter in ≥20% RT-CT slices was significantly larger at the superior segment (38/155) than at the middle (14/155) and inferior segments (18/155) of the prostatic urethra (p < 0.0167). CONCLUSIONS: The urethral position with a Foley catheter is different from the urethral position with a thin and soft guide-wire in a significant proportion of the patients. This should be taken into account for the PRV of the urethra to ensure precise radiotherapy such as in urethra-sparing radiotherapy.
  • Takayuki Hashimoto, Shinichi Shimizu, Seishin Takao, Shunsuke Terasaka, Akihiro Iguchi, Hiroyuki Kobayashi, Takashi Mori, Takaaki Yoshimura, Yuto Matsuo, Masaya Tamura, Taeko Matsuura, Yoichi M Ito, Rikiya Onimaru, Hiroki Shirato
    Journal of radiation research 60 (4) 527 - 537 0449-3060 2019/07/01 [Refereed][Not invited]
     
    The outcomes of intensity-modulated proton craniospinal irradiation (ipCSI) are unclear. We evaluated the clinical benefit of our newly developed ipCSI system that incorporates two gantry-mounted orthogonal online X-ray imagers with a robotic six-degrees-of-freedom patient table. Nine patients (7-19 years old) were treated with ipCSI. The prescribed dose for CSI ranged from 23.4 to 36.0 Gy (relative biological effectiveness) in 13-20 fractions. Four adolescent and young adult (AYA) patients (15 years or older) were treated with vertebral-body-sparing ipCSI (VBSipCSI). Myelosuppression following VBSipCSI was compared with that of eight AYA patients treated with photon CSI at the same institution previously. The mean homogeneity index (HI) in the nine patients was 0.056 (95% confidence interval: 0.044-0.068). The mean time from the start to the end of all beam delivery was 37 min 39 s ± 2 min 24 s (minimum to maximum: 22 min 49 s - 42 min 51 s). The nadir white blood cell, hemoglobin, and platelet levels during the 4 weeks following the end of the CSI were significantly higher in the VBSipCSI group than in the photon CSI group (P = 0.0071, 0.0453, 0.0024, respectively). The levels at 4 weeks after the end of CSI were significantly higher in the VBSipCSI group than in the photon CSI group (P = 0.0023, 0.0414, 0.0061). Image-guided ipCSI was deliverable in a reasonable time with sufficient HI. Using VBSipCSI, AYA patients experienced a lower incidence of serious acute hematological toxicity than AYA patients treated with photon CSI.
  • Ueno K, Matsuura T, Hirayama S, Takao S, Ueda H, Matsuo Y, Yoshimura T, Umegaki K
    Journal of applied clinical medical physics 20 (7) 48 - 57 1526-9914 2019/06 [Refereed][Not invited]
  • Takaaki Yoshimura, Rumiko Kinoshita, Shunsuke Onodera, Chie Toramatsu, Ryusuke Suzuki, Yoichi M. Ito, Seishin Takao, Taeko Matsuura, Yuka Matsuzaki, Kikuo Umegaki, Hiroki Shirato, Shinichi Shimizu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS 32 (9) 1095 - 1102 1120-1797 2016/09 [Refereed][Not invited]
     
    Purpose: This treatment planning study was conducted to determine whether spot scanning proton beam therapy (SSPT) reduces the risk of grade >= 3 hematologic toxicity (HT3+) compared with intensity modulated radiation therapy (IMRT) for postoperative whole pelvic radiation therapy (WPRT). Methods and materials: The normal tissue complication probability (NTCP) of the risk of HT3+ was used as an in silico surrogate marker in this analysis. IMRT and SSPT plans were created for 13 gynecologic malignancy patients who had received hysterectomies. The IMRT plans were generated using the 7-fields step and shoot technique. The SSPT plans were generated using anterior-posterior field with single field optimization. Using the relative biological effectives (RBE) value of 1.0 for IMRT and 1.1 for SSPT, the prescribed dose was 45 Gy(RBE) in 1.8 Gy(RBE) per fractions for 95% of the planning target volume (PTV). The homogeneity index (HI) and the conformity index (CI) of the PTV were also compared. Results: The bone marrow (BM) and femoral head doses using SSPT were significantly lower than with IMRT. The NTCP modeling analysis showed that the risk of HT3+ using SSPT was significantly lower than with IMRT (NTCP = 0.04 +/- 0.01 and 0.19 +/- 0.03, p = 0.0002, respectively). There were no significant differences in the CI and HI of the PTV between IMRT and SSPT (CI = 0.97 +/- 0.01 and 0.96 +/- 0.02, p = 0.3177, and HI = 1.24 +/- 0.11 and 1.27 +/- 0.05, p = 0.8473, respectively). Conclusion: The SSPT achieves significant reductions in the dose to BM without compromising target coverage, compared with IMRT. The NTCP value for HT3+ in SSPT was significantly lower than in IMRT. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.
  • Kenichiro Maeda, Takashi Ohno, Shizuka Igarashi, Takaaki Yoshimura, Koji Yamashiro, Masaharu Sakai
    GENE 505 (2) 374 - 378 0378-1119 2012/09 [Refereed][Not invited]
     
    Aldehyde oxidase is a member of the molybd-flavo enzyme family that catalyzes the hydroxylation of heterocycles and the oxidation of aldehydes into corresponding carboxylic acids. Aldehyde oxidase-1 (AOX1) is highly expressed in liver and is involved in the oxidation of a variety of aldehydes and nitrogenous heterocyclic compounds, including anti-cancer and immunosuppressive drugs. However, the physiological substrates of AOX1 have not been identified, and it was unknown how the expression of AOX1 is regulated. Here, we found that the AOX1 gene is regulated by the Nrf2 pathway. Two Nrf2 binding consensus elements (antioxidant responsive element, ARE) are located in the 5' upstream region of the rat AOX1 gene. Molecular analyses using reporter transfection analysis, EMSA, and ChIP analysis show that Nrf2 binds to and strongly activates the rat AOX1 gene. (C) 2012 Elsevier B.V. All rights reserved.

MISC

Books etc

  • A Decade of Health Sciences in Asia: Looking Back at the FHS International Conference
    Faculty of Health Sciences, Hokkaido University 2023/03 (ISBN: 9784600011901)

Teaching Experience

  • Inter-Graduate School Classes(Educational Program):Health, Society and Environment Health, Society and Environment IV _Health SciencesInter-Graduate School Classes(Educational Program):Health, Society and Environment Health, Society and Environment IV _Health Sciences Hokkaido University
  • Health SciencesHealth Sciences Hokkaido University
  • Laboratory Exercise in RadiochemistryLaboratory Exercise in Radiochemistry Hokkaido University
  • Practical medical imagingPractical medical imaging Hokkaido University
  • Principles of Medicine Medical AI: Data Handling WorkshopsPrinciples of Medicine Medical AI: Data Handling Workshops Hokkaido University
  • Principles of Medicine Medical AI: AI for Diagnosis and TherapyPrinciples of Medicine Medical AI: AI for Diagnosis and Therapy Hokkaido University
  • Principles of Medicine Medical AI: Medical AI SeminarPrinciples of Medicine Medical AI: Medical AI Seminar Hokkaido University
  • Basic Principles of Medicine Medical AI: Medical AI SeminarBasic Principles of Medicine Medical AI: Medical AI Seminar Hokkaido University
  • Basic Principles of Medicine Medical AI: AI for Diagnosis and TherapyBasic Principles of Medicine Medical AI: AI for Diagnosis and Therapy Hokkaido University
  • Basic Principles of Medicine Medical AI: Data Handling WorkshopsBasic Principles of Medicine Medical AI: Data Handling Workshops Hokkaido University
  • Supervised Individual Research of Health SciencesSupervised Individual Research of Health Sciences Hokkaido University
  • Supervised Individual Study of Health SciencesSupervised Individual Study of Health Sciences Hokkaido University
  • Introduction to Health Sciences and MedicineIntroduction to Health Sciences and Medicine Hokkaido University
  • Medical InformaticsMedical Informatics Hokkaido University
  • Practice in Medical EquipmentPractice in Medical Equipment Hokkaido University
  • Practice in Radiation Therapy TechnologyPractice in Radiation Therapy Technology Hokkaido University
  • Practice in Basic Clinical ImagingPractice in Basic Clinical Imaging Hokkaido University
  • Radiation OncologyRadiation Oncology Hokkaido University
  • Seminar on AnatomySeminar on Anatomy Hokkaido University
  • Clinical Practice Ⅰ~ⅥClinical Practice Ⅰ~Ⅵ Hokkaido University
  • Graduation ResearchGraduation Research Hokkaido University
  • Practice in Radiation Detection and DosimetryPractice in Radiation Detection and Dosimetry Hokkaido University

Association Memberships

  • Japanese Association for Medical Artificial Intelligence   Japan Association for Medical Informatics   Particle Therapy Co-Operative Group (PTCOG)   JAPANESE SOCIETY OF RADIOLOGICAL TECHNOLOGY   JAPANESE SOCIETY FOR RADIATION ONCOLOGY   JAPAN SOCIETY OF MEDICAL PHYSICS   THE JAPAN ASSOCIATION OF RADIOLOGICAL TECHNOLOGISTS   

Research Projects

  • Japan Society for the Promotion of Science:Grants-in-Aid for Scientific Research
    Date (from‐to) : 2024/04 -2027/03 
    Author : 小橋 啓司, 橋本 孝之, 吉村 高明, 西岡 健太郎
  • Japan Society for the Promotion of Science:Grants-in-Aid for Scientific Research
    Date (from‐to) : 2022/04 -2026/03 
    Author : 吉村 高明
  • 日本学術振興会:科学研究費助成事業 基盤研究(C)
    Date (from‐to) : 2022/04 -2025/03 
    Author : 橋本 孝之, 高尾 聖心, 小橋 啓司, 吉村 高明, 西岡 健太郎
  • Office of Diversity, Equity, and Inclusion, Hokkaido University:
    Date (from‐to) : 2023/04 -2025/03 
    Author : Takaaki Yoshimura
  • 医療AIを活用した前立腺癌に対する寡分割Adaptive陽子線治療技術開発
    Northern Advancement Center for Science & Technology (NOASTEC):Promotion for Young Research Talent and Network
    Date (from‐to) : 2023/08 -2024/03 
    Author : Takaaki Yoshimura
  • Akiyama Life Science Foundation:2023年度 研究助成〈奨励〉
    Date (from‐to) : 2023/04 -2024/03 
    Author : Yoshimura T
  • Hokkaido University:The 9th Hokkaido University Cross-Departmental Symposium Bronze Prize
    Date (from‐to) : 2023/10 -2023/10 
    Author : Yoshimura T, Sugimori H, Hirata K, Togo R
  • Northern Advancement Center for Science & Technology (NOASTEC):Promotion for Young Research Talent and Network
    Date (from‐to) : 2022/08 -2023/03 
    Author : Takaaki Yoshimura
  • 人獣連携によりMR画像-CT画像変換を高精度化する技術の開発~前立腺癌に対するMR画像誘導即時適応尿道線量低減陽子線治療の実現に向けて~
    Hokkaido University:第8回北海道大学部局横断シンポジウム研究助成採択 銅賞
    Date (from‐to) : 2022/10 -2022/10 
    Author : Yoshimura T, Shinbo G, Matsuura T, Hashimoto T, Nishioka K, Mori T, Kanehira T, Sugimori H
  • Japan Society for the Promotion of Science (JSPS):Early-Career Scientists
    Date (from‐to) : 2018/04 -2022/03 
    Author : Yoshimura Takaaki
     
    Urethra-sparing radiation therapy for localized prostate cancer can reduce the risk of radiation-induced genitourinary toxicity by intentionally underdosing the periurethral transitional zone. We proposed a method using post-urination high resolution T2-weighted 3.0 T MRI (PU-MRI) in urethra-sparing treatment planning. Our results demonstrated that the inter-operator prostatic urinary tract Region of Interest (ROI) matched with a high accuracy, not only in CT with a urethral catheter, but also in PU-MRI. Thus, PU-MRI is useful in identifying the urethra non-invasively, without using a urethral catheter. Moreover, compared with the conventional clinically applied plans, urethra-sparing proton therapy have potential clinical advantages and may reduce the risk of genitourinary toxicities, while maintaining the same tumor control probability and normal tissue complication probability in the rectum and bladder. And there were expectations for the promotion of future research.
  • 人工知能を用いた前立腺がんに対する 動体追跡陽子線治療計画技術の開発
    Northern Advancement Center for Science & Technology (NOASTEC):NOASTEC Presidential Prize
    Date (from‐to) : 2022/03 -2022/03 
    Author : Yoshimura T
  • Nothern Advancement Center for Science & Technology:Grants-in-Aid for Regional R&D Proposal-Based Program
    Date (from‐to) : 2021/08 -2022/03 
    Author : Yoshimura Takaaki
  • Japan Society for the Promotion of Science:Grants-in-Aid for Scientific Research Grant-in-Aid for Scientific Research (B)
    Date (from‐to) : 2018/04 -2021/03 
    Author : Shimizu Shinichi
     
    In the real-time tumor tracking radiotherapy, feature point information, that is used for gating, is obtained by fluoroscopic X-ray images. There still problems exist:1.X-ray exposure from diagnostic X ray that used for gating 2.insertion of a gold marker etc. as a feature pointReduce or eliminate X-ray exposure by making the observing area through diagnostic X-rays as small as possible to acquire target movement information or establishing the method of processing gating information obtained using MRI technology without using fluoroscopy were considered to be the goal of this study. X-rays are still optimal for acquiring organ motion information within human body necessary for gating treatment in real time, but a method for limiting the range was achieved in this study. In addition, we succeeded in trying to visualize the position of organs with MRI image data without using X-rays when preparing for treatment, and there were expectations for the promotion of future research.
  • Nothern Advancement Center for Science & Technology:Grants-in-Aid for Regional R&D Proposal-Based Program
    Date (from‐to) : 2020/08 -2021/03 
    Author : Takaaki Yoshimura
  • Nothern Advancement Center for Science & Technology:Grants-in-Aid for Regional R&D Proposal-Based Program
    Date (from‐to) : 2019/08 -2020/03 
    Author : Takaaki Yoshimura
  • the 58th PTCOG Travel Fellowship Award
    Particle Therapy Co-Operative Group:PTCOG Travel Fellowship Program
    Date (from‐to) : 2019/06 -2019/06 
    Author : Yoshimura T
  • Japan Society for the Promotion of Science:Grants-in-Aid for Scientific Research Grant-in-Aid for Young Scientists (B)
    Date (from‐to) : 2015/04 -2019/03 
    Author : Kinoshita Rumiko, Yoshimura Takaaki
     
    IMRT and spot sccaning proton therapy(SSPT) plans were created for 13 gynecologic malignancy patients who had received hysterectomies and irradiation to the pelvic region. The Bone marrow(BM)dose using SSPT was significantly lower than with IMRT. The NTCP modeling analysis showed that the risk of grade≧3 hematologic toxicity (HT3+) using SSPT was significantly lower than with IMRT The SSPT achieves significant reductions in the dose to BM without compromising target coverage, compared with IMRT. The NTCP value for HT3+ in SSPT was significantly lower than in IMRT. Dose volume anlaysis was carried out to eveluate the dose to the internal mammary lymph node(IMN) and normal tissure using 50 patients who reieved breaset concervation therapy(BCT). The IMN-PTV mean doses were less than 30 Gy in all cases.The IMN dose in standard tangential irradiation for BCT is insufficient for treatment.


Copyright © MEDIA FUSION Co.,Ltd. All rights reserved.