八木 泰憲 (ヤギ ヤスノリ)
医学研究院 外科系部門 侵襲制御医学分野 | 助教 |
北海道大学病院 | 助教 |
Last Updated :2024/12/06
■研究者基本情報
Researchmap個人ページ
J-Global ID
■研究活動情報
論文
- Differences of cerebral oxygen saturation in dialysis patients: a comparison of three principals of near infrared spectroscopy.
Yasunori Yagi, Yasunori Kubo, Koji Hoshino, Kazufumi Okada, Kiyohiko Hotta, Nobuo Shinohara, Yuji Morimoto
Journal of anesthesia, 37, 6, 861, 867, 2023年12月, [国内誌]
英語, 研究論文(学術雑誌), PURPOSE: It has been reported that cerebral oxygen saturation (rSO2) measured by near infrared spectroscopy is low in dialysis patients. We compared the rSO2 values of dialysis patients before living donor kidney transplantation and their donors as controls by using three spectroscopes that utilize different principals, the INVOS 5100C (spatially resolved spectroscopy), FORE-SIGHT ELITE (modified Beer-Lambert law) and tNIRS-1 (time-resolved spectroscopy). METHODS: Before induction of anesthesia, the sensors of one of the three spectroscopes were placed on the forehead and rSO2 values were recorded followed by the same measurement using the other two spectroscopes. The primary objective was to compare the rSO2 values of the dialysis patients and controls using the three spectroscopes by the unpaired t test. Then we compared the rSO2 values among the spectroscopes in both dialysis patients and controls by one-way ANOVA. Finally, we examined the relations between the rSO2 values and the physiological values by using the Pearson correlation coefficient. RESULTS: Fifteen pairs of dialysis patients and controls were studied. With the INVOS 5100 C, the values of the dialysis patients (59.7 ± 9.7% (mean ± standard deviation) were 13% lower than those of the controls (73.3 ± 6.9%) (P < 0.01). With the tNIRS-1, the values were 57.8 ± 4.8% in the dialysis patients and 63.3 ± 3.5% in the controls (P < 0.01). Almost no differences were observed with the FORE-SIGHT ELITE (71.6 ± 4.9% [dialysis patients] vs. 70.8 ± 4.3% [Controls]) (P = 0.62). Among the spectroscopes, the values were significantly different in both dialysis patients and controls. For the INVOS 5100C and tNIRS-1, correlation coefficients between rSO2 values and blood Hb and serum Alb were more than 0.5. CONCLUSIONS: The rSO2 values for comparisons between the dialysis patients and the controls were different according to differences of the principles of the near infrared spectroscopes. In the INVOS 5100C and tNIRS-1, rSO2 values may be related to blood Hb and serum Alb. - Intraoperative myocardial infarction and refractory cardiogenic shock during major hepatectomy: a case report
Yasunori Yagi, Kazuyuki Mizunoya, Toshihiro Mori, Hitoshi Saito, Yuji Morimoto
JA Clinical Reports, 8, 1, Springer Science and Business Media LLC, 2022年12月
研究論文(学術雑誌), Abstract
Background
Myocardial infarction (MI) complicated by cardiogenic shock during non-cardiac surgery is a rare but fatal complication. The management of intraoperative MI is challenging.
Case presentation
A 77-year-old hypertensive man with good functional capacity was scheduled for hepatectomy. After the start of liver resection, the electrocardiogram monitor showed ST depression, and the patient developed refractory cardiogenic shock. Transesophageal echocardiography revealed severe hypokinesis of the anteroseptal wall. The surgery was suspended, and an intra-aortic balloon pump was placed following immediate abdominal closure. Coronary angiography revealed severe stenosis of the left main coronary trunk, and percutaneous coronary intervention (PCI) was performed. Myocardial wall motion improved, and blood pressure stabilized. Two days after PCI, hepatectomy, which had been suspended, was successfully completed.
Conclusions
Once intraoperative MI has occurred, early diagnosis and multidisciplinary approaches are important to manage the difficult clinical situation. - Altered microvascular reactivity assessed by near-infrared spectroscopy after hepato-pancreato-biliary surgery
Kazuyuki Mizunoya, Yasunori Yagi, Yuji Morimoto, Satoshi Hirano
Journal of Clinical Monitoring and Computing, 36, 3, 703, 712, Springer Science and Business Media LLC, 2022年06月
研究論文(学術雑誌) - Diagnostic timing dependent characteristics of acute kidney injury following hepatectomy: a retrospective historical cohort analysis
Kazuyuki Mizunoya, Yasunori Yagi, Hirofumi Kamachi, Toshiya Kamiyama, Yuji Morimoto, Akinobu Taketomi
HPB, 23, 12, 1897, 1905, Elsevier BV, 2021年12月
研究論文(学術雑誌) - 術前心血管合併症低リスク患者において肝切除術中に心筋梗塞をきたした一例
八木 泰憲, 水野谷 和之, 森 敏洋, 斉藤 仁志, 森本 裕二
Cardiovascular Anesthesia, 24, Suppl., 140, 140, (一社)日本心臓血管麻酔学会, 2020年09月
日本語 - Anesthetic management by blockage of thoracoabdominal nerves through perichondrial approach (TAPA) for open nephrectomy in a pediatric patient with Wilms tumor
Nobuhiro Tanaka, Yasunori Yagi, Katsuhiro Aikawa, Yuji Morimoto
Journal of Clinical Anesthesia, 59, 51, 52, Elsevier BV, 2020年02月
研究論文(学術雑誌) - Changes of Cerebral Oxygenation in Sequential Glenn and Fontan Procedures in the Same Children
Yasunori Yagi, Masataka Yamamoto, Hitoshi Saito, Toshihiro Mori, Yuji Morimoto, Takayoshi Oyasu, Tsuyoshi Tachibana, Yoichi M. Ito
Pediatric Cardiology, 38, 6, 1215, 1219, Springer Science and Business Media LLC, 2017年08月
研究論文(学術雑誌)