SEARCH
Search Details
Watanabe Ryosuke
| Hokkaido University Hospital Division of Neural and Sensory Organs Otolaryngology-Head and Neck Surgery | Specially Appointed Assistant Professor |
Researcher basic information
■ URLresearchmap URLホームページURL■ Various IDs
J-Global ID
Research activity information
■ Papers- Objective evaluation for endoscopic sinus surgeries' proficiency by image analysis for postoperative 3D sinus models.
Kaito Yamada; Masanobu Suzuki; Kou Miyaji; Kazuya Sase; Koki Ebina; Teppei Tsujita; Xiaoshuai Chen; Shunsuke Komizunai; Taku Senoo; Akira Nakazono; Ryosuke Watanabe; Shogo Kimura; Takayoshi Suzuki; Yuji Nakamaru; Kotaro Matoba; Dominik Hinder; Alexander Zhang; Alkis J Psaltis; Peter J Wormald; Atsushi Konno; Akihiro Homma
Auris, nasus, larynx, 52, 5, 567, 574, Oct. 2025, [International Magazine]
English, Scientific journal, OBJECTIVE: Objective assessment for endoscopic sinus surgery skill proficiency is challenging, partly due to the great diversity of anatomies. Recently developed 3D-printed sinus models provide standardized anatomy with realistic tissue-feel. In this study, we developed a method to evaluate endoscopic sinus surgery skill proficiency through pre- and post-operative image analysis of CT images of dissected 3D sinus models and validated it by comparing to other surgical proficiency indices. METHODS: Forty-seven otolaryngologists performed endoscopic sinus surgery for 3D sinus models. CT images of each postoperative 3D model were taken. The region growing method, an image segmentation technique, was utilized to assess the surgical space expansion. The region of interest (ROI) was defined as the space within nasal cavity and paranasal sinuses and continuous from the anterior nostril with a width of >4.00 mm kept. The volume of ROI was estimated and compared with conventional assessment methods such as board-certification, the objective structured assessment of technical skills score, and the number of experienced surgery cases. Further, the 3D-CG images of ROI were created. The completion of surgical steps within the allocated time was evaluated based on the 3D-CG and compared with the recorded endoscopic video. RESULTS: The volume in postoperative models was 24.48±4.34 cm3 across all participants, respectively. The postoperative volume was significantly larger in board-certified participants (certified; 25.51±4.22 cm3 vs. uncertified; 22.87±4.14 cm3, p = 0.03). The volume is positively correlated to the objective structured assessment of technical skills score (r = 0.72, p < 0.01) and the number of experienced cases (r = 0.51, p = 0.01). The accuracy of the 3D-CG judgement for completion of a surgical middle meatal antrostomy, sphenoidotomy, and frontal sinusotomy were 91.3 %, 69.6 %, and 84.8 %, when compared to recorded endoscopic video, with high sensitivity and specificity. CONCLUSION: The combination of standardized 3D models and image analysis provides a simple and objective tool for the assessment of surgical skill proficiency. - 発がん関連因子TRIM27の分子メカニズムに関する検討
木村 将吾; 中丸 裕爾; 鈴木 正宣; 中薗 彬; 本間 あや; 渡邉 良亮; 本間 明宏; 畠山 鎮次
日本耳鼻咽喉科免疫アレルギー感染症学会抄録集, 5回, 167, 167, 日本耳鼻咽喉科免疫アレルギー感染症学会, Apr. 2025
Japanese - Motion analysis for objective evaluation of psychomotor skills in Endoscopic Sinus Surgery
K Miyaji; M Suzuki; R Watanabe; T Suzuki; K Matoba; A Nakazono; Y Nakamaru; K Ebina; T Abe; D Hinder; A J Psaltis; P J Wormald; A Homma; A Konno
Rhinology Journal, Stichting Nase, 01 Dec. 2024
Scientific journal, Background: This study aims to digitalize surgical maneuvers in ESS using a motion capture system under standardized conditionsprovided by 3D printed-sinus models. Methodology: Forty-seven otolaryngologists performed ESS on 3D printed modelsmanufactured from computed tomography (CT) images of actual patients. Participants were classified to 3 groups according tothe objective structured technical skills assessment score. All surgical maneuverers performed during ESS were captured by amotion capture system. The path length, velocity, acceleration, and jerk were calculated for each surgical instrument and comparedamong the groups. Principle Component Analysis (PCA) was utilized to identify which metrics reflected surgical skill level. Inaddition, ten registrars repeated the surgical dissection. Their motion metrics were also compared between first training and therepeated training and then subjected to the PCA. Results: Several metrics such as the angular acceleration and jerk of the cuttingforceps were identified by PCA as possible indicators distinguishing the different skill levels for the ESS maneuvers. PCA analysis inthe repetitive training also found the angular metrics of the upturned-cutting forceps correlating to their skill improvement.Conclusions: Combined with the validated 3D-printed sinus models, the motion capture system provided the objective evaluationof the surgical performances of ESS. - 鼻副鼻腔粘膜悪性黒色腫におけるTRIM27の検討
木村 将吾; 中丸 裕爾; 鈴木 正宣; 中薗 彬; 本間 あや; 渡邉 良亮; 加納 里志; 対馬 那由多; 鈴木 崇祥; 井戸川 寛志; 本間 明宏; 渡部 昌; 近藤 豪; 畠山 鎮次
日本鼻科学会会誌, 63, 3, 336, 336, (一社)日本鼻科学会, Sep. 2024
Japanese - 鼻副鼻腔粘膜悪性黒色腫におけるTRIM27の検討
木村 将吾; 中丸 裕爾; 鈴木 正宣; 中薗 彬; 本間 あや; 渡邉 良亮; 加納 里志; 対馬 那由多; 鈴木 崇祥; 井戸川 寛志; 本間 明宏; 渡部 昌; 近藤 豪; 畠山 鎮次
日本鼻科学会会誌, 63, 3, 336, 336, (一社)日本鼻科学会, Sep. 2024
Japanese - Long-term results of nasolacrimal duct and inferior turbinate swing technique for inverted papilloma of the maxillary sinus.
Yuji Nakamaru; Masanobu Suzuki; Ken Shizuki; Aya Honma; Akira Nakazono; Shogo Kimura; Ryosuke Watanabe; Satoshi Kano; Nayuta Tsushima; Takayoshi Suzuki; Akihiro Homma
SAGE open medicine, 12, 20503121241271877, 20503121241271877, 2024, [International Magazine]
English, Scientific journal, BACKGROUND: We developed a technique to preserve the entire nasolacrimal duct and inferior turbinate, by swinging the nasolacrimal duct upward and the inferior turbinate backward; that is, a nasolacrimal duct and inferior turbinate swing technique for sinonasal inverted papilloma of the maxillary sinus. In this study, we evaluated the long-term results of this technique. METHODS: A retrospective analysis was performed on the data for 53 consecutive pathologically confirmed inverted papilloma patients who were treated using nasolacrimal duct and inferior turbinate swing technique. The frequency of recurrence, the degree of nasolacrimal duct and inferior turbinate preservation, and the frequency of adverse events were assessed. RESULTS: The median follow-up period was 51 months (mean 62.5 months; range 10-187 months). No cases of recurrence within the maxillary sinus were observed among the cases treated using this technique, whereas three (5.7%) of the 53 cases experienced recurrence in areas other than the maxillary sinus. We could preserve the nasolacrimal duct in all cases. On the other hand, the inferior turbinate was resected during surgery in one case. No epiphora, dacryocystiits, numbness of the cheek, or collapse of the ala of the nose was observed. CONCLUSION: This nasolacrimal duct and inferior turbinate swing technique method is a safe and effective method for the excision of primary or recurrent inverted papilloma and demonstrates low rates of recurrence and complications. - Can high-fidelity 3D models be a good alternative for cadaveric materials in skill assessment for endoscopic sinus surgery? A comparison study in assessment for surgical performance in 3D models and cadavers.
Masanobu Suzuki; Ryosuke Watanabe; Akira Nakazono; Yuji Nakamaru; Takayoshi Suzuki; Shogo Kimura; Kotaro Matoba; Manabu Murakami; Dominik Hinder; A J Psaltis; Akihiro Homma; P J Wormald
Frontiers in medicine, 11, 1301511, 1301511, 2024, [International Magazine]
English, Scientific journal, INTRODUCTION: Traditionally formal assessment of surgical skills has not been part of a surgeon's accreditation process. The widely adopted apprentice model of "on-the-job training" does create additional risk for the patients. In the past surgical training has used cadavers, but these are expensive, require dedicated wet-lab facilities and are in increasingly short supply. In many countries religious and cultural practices also preclude cadaveric use. Recent 3D-printed technology allows mass reproduction of high-fidelity 3D models. In this study, we examined the utility of 3D sinus models compared to cadaver dissection for surgical skill assessment for endoscopic sinus surgery (ESS). MATERIALS AND METHODS: A total of 17 otolaryngologists performed Endoscopic Sinus Surgery (ESS) on 3D printed sinus models and then repeated these procedures on cadavers. Their surgical performance was assessed with the Objective Structured Assessment of Technical Skills (OSATS) score for ESS and time was taken to complete an ESS procedure. Their performance on the 3D models and cadavers was compared. RESULTS: There were no significant differences in the OSATS score between 3D models and cadavers (50.41 ± 13.31 vs. 48.29 ± 16.01, p = 0.36). There was a strong positive correlation between the score in 3D models and those in cadavers (r = 0.84, p < 0.001). No significant differences were found in time for a mini-ESS (21:29 ± 0:10 vs. 20:33 ± 0:07, p = 0.53). There were positive correlations between 3D models and cadavers in time taken for a mini-ESS (r = 0.55, p = 0.04). CONCLUSION: The surgical performance on the 3D models was comparable to that on cadavers. This supports the utility of the 3D models as an inexhaustible alternative for cadavers in ESS surgical skill assessment. - Mental workload during endoscopic sinus surgery is associated with surgeons' skill levels.
Masanobu Suzuki; Kou Miyaji; Kotaro Matoba; Takashige Abe; Yuji Nakamaru; Ryosuke Watanabe; Takayoshi Suzuki; Akira Nakazono; Atsushi Konno; Dominik Hinder; A J Psaltis; P J Wormald; Akihiro Homma
Frontiers in medicine, 10, 1090743, 1090743, 2023, [International Magazine]
English, Scientific journal, INTRODUCTION: Surgeons' mental workload during endoscopic sinus surgery (ESS) has not been fully evaluated. The assessment was challenging due to the great diversity of each patient's anatomy and the consequence variety of surgical difficulties. In this study, we examined the mental workload of surgeons with various surgical skill levels during ESS under the standardized condition provided by novel-designed 3D sinus models. MATERIALS AND METHODS: Forty-seven participants performed a high-fidelity ESS simulation with 3D-printed sinus models. Surgeons' mental workload was assessed with the national aeronautics and space administration-task load index (NASA-TLX). Associations between the total and subscales score of NASA-TLX and surgical skill index, including the board certification status, the number of experienced ESS cases, and the objective structured assessment of technical skills (OSATS), were analyzed. In addition, 10 registrars repeated the simulation surgery, and their NASA-TLX score was compared before and after the repetitive training. RESULTS: The total NASA-TLX score was significantly associated with OSATS score (p = 0.0001). Primary component analysis classified the surgeons' mental burden into three different categories: (1) the skill-level-dependent factors (temporal demand, effort, and performance), (2) the skill-level-independent factors (mental and physical demand), and (3) frustration. After the repetitive training, the skill-level-dependent factors were alleviated (temporal demand; z = -2.3664, p = 0.0091, effort; z = -2.1704, p = 0.0346, and performance; z = -2.5992, p = 0.0017), the independent factors were increased (mental demand; z = -2.5992, p = 0.0023 and physical demand; z = -2.2509, p = 0.0213), and frustration did not change (p = 0.3625). CONCLUSION: Some of the mental workload during ESS is associated with surgical skill level and alleviated with repetitive training. However, other aspects remain a burden or could worsen even when surgeons have gained surgical experience. Routine assessment of registrars' mental burdens would be necessary during surgical training to sustain their mental health. - Repetitive simulation training with novel 3D-printed sinus models for functional endoscopic sinus surgeries.
Masanobu Suzuki; Kou Miyaji; Ryosuke Watanabe; Takayoshi Suzuki; Kotaro Matoba; Akira Nakazono; Yuji Nakamaru; Atsushi Konno; Alkis James Psaltis; Takashige Abe; Akihiro Homma; Peter-John Wormald
Laryngoscope investigative otolaryngology, 7, 4, 943, 954, Aug. 2022, [International Magazine]
English, Scientific journal, BACKGROUND: The purpose of this study was to find a utility of a newly developed 3D-printed sinus model and to evaluate the educational benefit of simulation training with the models for functional endoscopic sinus surgery (FESS). MATERIAL AND METHODS: Forty-seven otolaryngologists were categorized as experts (board-certified physicians with ≥200 experiences of FESS, n = 9), intermediates (board-certified physicians with <200 experiences of FESS, n = 19), and novices (registrars, n = 19). They performed FESS simulation training on 3D-printed models manufactured from DICOM images of computed tomography (CT) scan of real patients. Their surgical performance was assessed with the objective structured assessment of technical skills (OSATS) score and dissection quality evaluated radiologically with a postdissection CT scan. First we evaluated the face, content, and constructive values. Second we evaluated the educational benefit of the training. Ten novices underwent training (training group) and their outcomes were compared to the remaining novices without training (control group). The training group performed cadaveric FESS surgeries before and after the repetitive training. RESULTS: The feedback from experts revealed high face and content value of the 3D-printed models. Experts, intermediates, and novices demonstrated statistical differences in their OSATS scores (74.7 ± 3.6, 58.3 ± 10.1, and 43.1 ± 11.1, respectively, p < .001), and dissection quality (81.1 ± 13.1, 93.7 ± 15.1, and 126.4 ± 25.2, respectively, p < .001). The training group improved their OSATS score (41.1 ± 8.0 to 61.1 ± 6.9, p < .001) and dissection quality (122.1 ± 22.2 to 90.9 ± 10.3, p = .013), while the control group not. After training, 80% of novices with no prior FESS experiences completed surgeries on cadaver sinuses. CONCLUSION: Repeated training using the models revealed an initial learning curve in novices, which was confirmed in cadaveric mock FESS surgeries. LEVEL OF EVIDENCE: N/A. - Glossopharyngeal/vagus nerve disorder due to IgG4-related hypertrophic pachymeningitis.
Yui Kosumi; Hiroyuki Nakamura; Ryosuke Watanabe; Toshiyuki Watanabe; Tetsuya Horita
Rheumatology (Oxford, England), 30 Jan. 2019, [International Magazine]
English, Scientific journal
- Poly(I:C)刺激は鼻粘膜上皮細胞のHLA-G発現を亢進させる
渡邉 良亮; 鈴木 正宣; 中薗 彬; 木村 将吾; 本間 あや; 中丸 裕爾; 本間 明宏, 日本耳鼻咽喉科免疫アレルギー感染症学会抄録集, 5回, 204, 204, Apr. 2025
日本耳鼻咽喉科免疫アレルギー感染症学会, Japanese - 嗅神経芽細胞腫に対する内視鏡下頭蓋底手術および内視鏡併用の開頭手術の周術期における比較検討
中薗彬; 渡邉良亮; 木村将吾; 本間あや; 鈴木正宣; 中丸裕爾; 本間明宏, 日本鼻科学会会誌(Web), 63, 3, 2024 - 鼻副鼻腔粘膜悪性黒色腫におけるTRIM27の検討
木村将吾; 中丸裕爾; 鈴木正宣; 中薗彬; 本間あや; 渡邉良亮; 加納里志; 対馬那由多; 鈴木崇祥; 井戸川寛志; 本間明宏; 渡部昌; 近藤豪; 畠山鎮次, 日本鼻科学会会誌(Web), 63, 3, 2024 - 副鼻腔炎診療は変わったか?知っておくべき副鼻腔炎を伴う全身疾患 サルコイドーシス
渡邉良亮; 中丸裕爾, JOHNS, 39, 2, 2023 - 鼻中隔前弯の客観的な評価法を用いた鼻中隔矯正術の治療効果検討
木村将吾; 中丸裕爾; 鈴木正宣; 本間あや; 中薗彬; 渡邉良亮; 本間明宏, 日本鼻科学会会誌(Web), 62, 3, 2023 - 副鼻腔3Dモデルとモーションキャプチャーを用いたESS技量評価の試み
鈴木正宣; 鈴木正宣; 中丸裕爾; 渡邉良亮; 中薗彬; 木村将吾; 本間あや; WORMALD PJ; PSALTIS AJ; 本間明宏, 日本鼻科学会会誌(Web), 62, 3, 2023 - 副鼻腔3Dモデルを用いたESSトレーニングの妥当性・有効性の検討
鈴木正宣; 中丸裕爾; 渡邉良亮; 中薗彬; 木村将吾; 本間あや; WORMALD Peter-John; WORMALD Peter-John; PSALTIS Alkis-James; 本間明宏, 日本鼻科学会会誌(Web), 61, 3, 2022 - TRIM27の副鼻腔粘膜悪性黒色腫バイオマーカーとしての検討
木村将吾; 中丸裕爾; 鈴木正宣; 本間あや; 中薗彬; 渡邉良亮; 本間明宏, 日本鼻科学会会誌(Web), 61, 3, 2022 - 鼻副鼻腔扁平上皮癌に対する内視鏡下鼻副鼻腔手術
中丸裕爾; 鈴木正宣; 本間あや; 中薗彬; 木村将吾; 渡邉良亮; 本間明宏, 日本鼻科学会会誌(Web), 61, 3, 2022 - A case of mammary analogue secretory carcinoma of the parotid gland
渡邉良亮; 安川真一郎; 高橋紘樹; 蠣崎文彦, 耳鼻咽喉科・頭頚部外科, 93, 3, 2021 - A case of Eosinophilic granulomatosis with polyangiitis presented multiple lesions in head and neck
三嶽大貴; 渡邉良亮; 中丸裕爾; 本間明宏, 岩見沢市立総合病院医誌, 46, 1, 2020 - 左反回神経麻痺を契機に診断されたIgG4関連疾患の1例
小住由衣; 渡邊俊之; 宇都宮彩乃; 家坂光; 千葉幸輝; 老田真佑子; 中村浩之; 渡邉良亮; 丸茂弥生; 外丸詩野; 堀田哲也, 日本臨床リウマチ学会プログラム・抄録集, 33rd, 2018 - 頭頸部壊死性筋膜炎の1例
渡邉良亮; 加納里志; 中薗彬; 福田篤; 本間明宏, 日本頭頸部外科学会総会ならびに学術講演会プログラム・予稿集, 28th, 2018
